- Biotechnology: molecular diagnostics, reading DNA to answer questions
What is isothermal amplification?
Isothermal amplification copies DNA at a single, constant temperature instead of the repeated heating and cooling of PCR. A special polymerase pushes apart the two strands as it copies, so no heat is needed to separate them. The best-known method, LAMP, runs at about 60 to 65 °C, can make about a billion copies in under an hour, and can be read by eye.
The topic explained
Copying DNA without a thermal cycler
PCR copies DNA in cycles. The sample is heated to about 95 °C to separate the two strands, cooled to about 55 °C so the primers bind, and warmed to about 72 °C so the polymerase copies. A thermal cycler repeats this some thirty times. Isothermal amplification is a family of methods that copy DNA at one temperature throughout, so a simple heat block or water bath is enough.
The problem these methods solve is not chemistry but place. A thermal cycler needs power, precise control and a laboratory. A test that holds one temperature can run in a small box near a patient, in a field clinic or in a plant nursery. A common misreading is that the DNA is copied at room temperature. The temperature is constant, not low: LAMP, the best-known method, runs at about 60 to 65 °C.
How LAMP works
LAMP, loop-mediated isothermal amplification, was published by Tsugunori Notomi and colleagues at the Japanese company Eiken Chemical in 2000. It uses four primers that recognize six regions of the target, sometimes with two extra loop primers. Some primers carry a tail complementary to a nearby stretch, so each new strand folds back on itself into a loop that a fresh primer can bind. The product is a growing mix of copies of different lengths, which on a gel looks like a ladder instead of one band.
Because so many regions must match, LAMP is very specific. The original paper reported about copies of the target in less than an hour. Starting from 10 copies, that is a factor of , about 27 doublings, one every two minutes or so on average. The design that makes LAMP specific also makes it demanding: six regions must fit within a short stretch of the target, and primers that happen to pair with each other can give a false signal, so a new test takes careful design and checking.
Strand displacement instead of heat
In PCR, heat separates the strands. In LAMP the enzyme does it. The Bst polymerase, from a bacterium that lives in heat, has strand displacement activity: as it copies one strand, it pushes off the strand that was paired with it. The freed single strand is a new template for the next primer, so copying never has to stop for a heating step.
Students often think that any DNA polymerase would work at a steady 65 °C. The Taq polymerase of PCR copies well but does not push strands aside, so without the heating step its products would stay paired and the reaction would stall. The steady temperature still matters: it must suit the enzyme and be warm enough that primers bind only where they match well, not loosely in the wrong places.
Reading the result and its limits
Each nucleotide added to DNA releases pyrophosphate, and LAMP makes so much DNA that pyrophosphate joins magnesium in the mix into a white precipitate: a positive tube turns cloudy. Other versions add a dye that changes color, for example from pink to yellow, or glows under light. So a result can be read by eye. The method has limits: it detects but is not used for cloning, its many primers are harder to design, and testing for several targets in one tube is less developed than in PCR. It also tolerates substances in samples such as blood better than PCR does. In short, PCR remains the flexible tool of the laboratory, and isothermal amplification is the tool that takes molecular testing outside it.
Practice: isothermal amplification
For 12th grade biotechnology students. Answer each question from the sheet, show your calculations, then check your answers.
Free, no sign-up. The answer key prints on the second page. Regenerating a new worksheet on the same topic needs a free account.
What does the word isothermal mean, and what does isothermal amplification replace?
Fill in the label of the lower trace and say what it shows.
Fill in the two hidden cells for LAMP.
Fill in the missing step of the cycle and explain why it lets the reaction continue without heating.
A reaction starts with 10 copies and reaches copies. About how many doublings is that? Use .
Why does a positive LAMP tube turn cloudy?
Give one advantage of LAMP over PCR for a test far from a laboratory, and one limit of LAMP.
Common questions
Is LAMP as accurate as PCR?
LAMP is very specific because its primers must match six regions of the target. How well a particular test performs depends on its design and is measured as its sensitivity and specificity, like any test.
What temperature does LAMP use?
About 60 to 65 °C, held constant for the whole reaction. The original 2000 paper used 65 °C.
Why is Bst polymerase used instead of Taq?
Bst polymerase has strand displacement activity: it pushes apart the double strand ahead of it as it copies. Taq does not, so it needs heat to separate the strands.
Can isothermal amplification detect RNA viruses?
Yes, if a reverse transcriptase is added first to copy the viral RNA into DNA, as in RT-PCR. The DNA copy is then amplified at one temperature.
Are there isothermal methods other than LAMP?
Yes. Several methods copy DNA at a single temperature with different enzymes and primers; LAMP is the most widely used and the best example for the bagrut.

Still have a question? Ask Lessi
Any question about this subject. Lessi answers right here, step by step.
Try asking
Asking needs a free account; your question is kept while you sign up. Answers are written by AI and can contain mistakes. Lessi doesn’t give medical or legal advice.
Learn it with a teacher
Learn this topic live with Lessi
Lessi, the AI teacher, explains it out loud on a board, with short quizzes, at your pace. The first 60 minutes are free.