# What is isothermal amplification?

> Written with AI · [Biotechnology: molecular diagnostics, reading DNA to answer questions](https://lessoons.com/en/molecular-diagnostics) · Grade 12 · 2026-11-14 · https://lessoons.com/en/molecular-diagnostics/what-is-isothermal-amplification

Isothermal amplification copies DNA at a single, constant temperature instead of the repeated heating and cooling of PCR. A special polymerase pushes apart the two strands as it copies, so no heat is needed to separate them. The best-known method, LAMP, runs at about 60 to 65 °C, can make about a billion copies in under an hour, and can be read by eye.

## The topic explained

### Copying DNA without a thermal cycler

PCR copies DNA in cycles. The sample is heated to about 95 °C to separate the two strands, cooled to about 55 °C so the primers bind, and warmed to about 72 °C so the polymerase copies. A thermal cycler repeats this some thirty times. Isothermal amplification is a family of methods that copy DNA at one temperature throughout, so a simple heat block or water bath is enough.

The problem these methods solve is not chemistry but place. A thermal cycler needs power, precise control and a laboratory. A test that holds one temperature can run in a small box near a patient, in a field clinic or in a plant nursery. A common misreading is that the DNA is copied at room temperature. The temperature is constant, not low: LAMP, the best-known method, runs at about 60 to 65 °C.

### How LAMP works

LAMP, loop-mediated isothermal amplification, was published by Tsugunori Notomi and colleagues at the Japanese company Eiken Chemical in 2000. It uses four primers that recognize six regions of the target, sometimes with two extra loop primers. Some primers carry a tail complementary to a nearby stretch, so each new strand folds back on itself into a loop that a fresh primer can bind. The product is a growing mix of copies of different lengths, which on a gel looks like a ladder instead of one band.

Because so many regions must match, LAMP is very specific. The original paper reported about 10⁹ copies of the target in less than an hour. Starting from 10 copies, that is a factor of 10⁸ = 2^(26.6), about 27 doublings, one every two minutes or so on average. The design that makes LAMP specific also makes it demanding: six regions must fit within a short stretch of the target, and primers that happen to pair with each other can give a false signal, so a new test takes careful design and checking.

### Strand displacement instead of heat

In PCR, heat separates the strands. In LAMP the enzyme does it. The Bst polymerase, from a bacterium that lives in heat, has strand displacement activity: as it copies one strand, it pushes off the strand that was paired with it. The freed single strand is a new template for the next primer, so copying never has to stop for a heating step.

Students often think that any DNA polymerase would work at a steady 65 °C. The Taq polymerase of PCR copies well but does not push strands aside, so without the heating step its products would stay paired and the reaction would stall. The steady temperature still matters: it must suit the enzyme and be warm enough that primers bind only where they match well, not loosely in the wrong places.

### Reading the result and its limits

Each nucleotide added to DNA releases pyrophosphate, and LAMP makes so much DNA that pyrophosphate joins magnesium in the mix into a white precipitate: a positive tube turns cloudy. Other versions add a dye that changes color, for example from pink to yellow, or glows under light. So a result can be read by eye. The method has limits: it detects but is not used for cloning, its many primers are harder to design, and testing for several targets in one tube is less developed than in PCR. It also tolerates substances in samples such as blood better than PCR does. In short, PCR remains the flexible tool of the laboratory, and isothermal amplification is the tool that takes molecular testing outside it.

## Practice: isothermal amplification

For 12th grade biotechnology students. Answer each question from the sheet, show your calculations, then check your answers.

1. **What does the word isothermal mean, and what does isothermal amplification replace?** — Isothermal means at one, constant temperature. It replaces the repeated heating and cooling of PCR, so no thermal cycler is needed.
2. **Fill in the label of the lower trace and say what it shows.** — LAMP, held at about 60 to 65 °C. The temperature stays the same the whole time, unlike the cycles of PCR in the upper trace.
3. **Fill in the two hidden cells for LAMP.** — Temperature: steady, about 60 to 65 °C. The strands are parted by the polymerase, through strand displacement.
4. **Fill in the missing step of the cycle and explain why it lets the reaction continue without heating.** — The strand ahead is pushed off by the polymerase. That frees a single strand that a new primer can bind, so copying continues without a heating step.
5. **A reaction starts with 10 copies and reaches 10⁹ copies. About how many doublings is that? Use 2¹⁰ ≈ 10³.** — A factor of 10⁸. Since 2¹⁰ ≈ 10³, 10⁸ ≈ 2^(26.6), so about 27 doublings.
6. **Why does a positive LAMP tube turn cloudy?** — Every nucleotide added releases pyrophosphate. So much DNA is made that the pyrophosphate forms an insoluble precipitate with magnesium, which makes the liquid cloudy.
7. **Give one advantage of LAMP over PCR for a test far from a laboratory, and one limit of LAMP.** — Advantage: it needs only one temperature, so a heat block or bath is enough, and the result can be read by eye. Limit: for example, it is hard to design, not used for cloning, and less suited to testing several targets in one tube.

## Common questions

### Is LAMP as accurate as PCR?

LAMP is very specific because its primers must match six regions of the target. How well a particular test performs depends on its design and is measured as its sensitivity and specificity, like any test.

### What temperature does LAMP use?

About 60 to 65 °C, held constant for the whole reaction. The original 2000 paper used 65 °C.

### Why is Bst polymerase used instead of Taq?

Bst polymerase has strand displacement activity: it pushes apart the double strand ahead of it as it copies. Taq does not, so it needs heat to separate the strands.

### Can isothermal amplification detect RNA viruses?

Yes, if a reverse transcriptase is added first to copy the viral RNA into DNA, as in RT-PCR. The DNA copy is then amplified at one temperature.

### Are there isothermal methods other than LAMP?

Yes. Several methods copy DNA at a single temperature with different enzymes and primers; LAMP is the most widely used and the best example for the bagrut.