# What is aseptic technique?

> Written with AI · [Cell technologies: growing, guiding and copying cells](https://lessoons.com/en/cell-technologies) · Grade 11 · 2026-11-12 · https://lessoons.com/en/cell-technologies/what-is-aseptic-technique

Aseptic technique is the set of working habits that keeps microbes out of a sterile culture: working in a biological safety cabinet, wiping surfaces with 70% ethanol, sterilizing media and tools, and opening one vessel at a time. It matters because a single bacterium can double every 20 minutes and take over a flask of slow-growing animal cells within a day.

## The topic explained

### Keeping microbes out, not killing them in

Many animal cell lines double about once a day; a bacterium such as E. coli can double every 20 minutes. In ten hours that is 30 doublings, and one bacterium becomes over a billion. So a culture is lost not to a crowd of microbes but to one that gets in. Aseptic technique is the set of habits that stops that one from getting in.

Two words are often mixed up. Sterilization kills every living thing on an object or in a liquid, for example in an autoclave. Aseptic technique keeps sterile things sterile while you work with them. The room is not sterile and does not need to be: what matters is that every route from it into the culture is blocked.

### The cabinet: a wall of clean air

Cell work is done in a biological safety cabinet. In the common class II cabinet, a HEPA filter, which traps nearly all particles, including bacteria and spores, sends clean air down onto the work surface; room air is drawn in at the front opening, so nothing drifts out toward the worker; and the air leaving the cabinet passes through a filter as well. One cabinet protects the culture, the worker and the room together.

The order of work follows from the airflow. Let the cabinet run before starting, wipe the surface with 70% ethanol, bring in only what is needed, and work in the middle, away from the front grille. Open one vessel at a time, never pass a hand over an open flask, and close everything before taking it out. A common mistake is to treat a horizontal clean bench as a safety cabinet: it blows filtered air out toward the worker, so it protects the culture but not the person.

### Sterilizing what goes in and what comes out

Glassware, tools and many solutions go into an autoclave: steam under pressure at 121 °C, hotter than boiling water can get in an open pot. Moist heat kills by destroying the proteins of every microbe, spores included. Liquids that heat would ruin, such as serum or a medium with vitamins, are pushed through a filter with pores of 0.22 micrometres, small enough to hold back bacteria. Used cultures and waste are autoclaved too, before they leave the laboratory.

Surfaces and gloves are wiped with 70% ethanol, not pure ethanol. The water matters: proteins are denatured faster when water is present, and pure alcohol evaporates before it has done its work.

### How to tell a culture is contaminated

Look at the flask every day. Bacteria make the medium cloudy, and the acid they produce turns the pH indicator, phenol red, from red to yellow within a day; under the microscope they are tiny moving dots between the cells. Yeast appear as oval particles that bud, and mold as thin threads. Mycoplasma, tiny bacteria with no cell wall, cloud nothing and are invisible under an ordinary microscope; a 2015 survey of public sequencing data found them in 11% of experiments. Only a test, often PCR, finds them.

Many laboratories do not add antibiotics routinely, because they can hide a low-level infection and do not act on mycoplasma. A contaminated flask is autoclaved and discarded, not rescued.

## Practice: aseptic technique in the cell laboratory

For 11th grade biotechnology students. Answer each question from the sheet, then check your work against the answers.

1. **What is the difference between sterilization and aseptic technique?** — Sterilization kills every living thing on an object or in a liquid, for example in an autoclave. Aseptic technique is the way of working that keeps sterile things sterile, so that no microbe gets in while you use them.
2. **Fill in the three missing barriers in the table.** — Hands and breath: gloves, a lab coat and no talking over open vessels. Surfaces: wiping with 70% ethanol. Other cell lines: working with one line at a time, with its own bottles of medium.
3. **Name the airflows A and B in the cabinet and say whom each one protects.** — A: clean, HEPA-filtered air flowing down onto the work surface; it protects the culture. B: room air drawn in at the front opening; it protects the worker, since nothing drifts out.
4. **Complete the diagram: how would you sterilize a glass bottle, and how a bottle of serum?** — If the item survives heat, like the glass bottle: an autoclave, steam under pressure at 121 °C. If it does not, like serum: filtration through a 0.22 micrometre filter.
5. **A bacterium doubles every 20 minutes. How many bacteria come from a single one in 10 hours, if nothing stops them?** — 10 hours = 600 minutes = 30 doublings. 2 to the power 30 = 1,073,741,824, over a billion bacteria, while animal cells that double once a day have not yet doubled once.
6. **Why is 70% ethanol used to wipe the cabinet and not pure ethanol?** — Water is needed for the alcohol to denature the proteins of microbes quickly, and pure ethanol evaporates too fast to work. A mixture of about 70% kills better.
7. **A flask was clear and red yesterday; today the medium is cloudy and yellow. What probably happened, and what should be done?** — Bacterial contamination: bacteria cloud the medium and their acid turns phenol red yellow. The flask should be closed, autoclaved and discarded, and the cabinet and incubator cleaned.

## Common questions

### Why don't laboratories just add antibiotics to every culture?

Routine antibiotics can hide a low-level infection that flares up when they are removed, encourage resistant bacteria and change how some cells behave. They also do not act on mycoplasma, which have no cell wall. Clean technique is the real protection.

### Is a laminar flow hood the same as a biological safety cabinet?

No. A horizontal laminar flow clean bench blows filtered air across the work and out toward the person, so it protects only the product. A class II biological safety cabinet also draws air in at the front and filters the exhaust, so it protects the worker and the room too.

### What does an autoclave do?

An autoclave sterilizes with steam under pressure, usually at 121 °C. The pressure lets steam get hotter than boiling water in an open pot, and the moist heat destroys the proteins of all microbes, including spores.

### Why is mycoplasma so hard to detect?

Mycoplasma are among the smallest bacteria, have no cell wall and do not make the medium cloudy. They cannot be seen under an ordinary light microscope, so laboratories test for them, often by PCR.

### Is aseptic technique used only with animal cells?

No. The same habits are used in microbiology, in plant tissue culture, in making medicines and in hospital procedures. The details differ, but the principle is the same: block every route by which a microbe could get in.